A field comparison of the thermal performance of ventilated and plastered façades in hot conditions using the climate of Southern Kazakhstan as an example: internal surface temperature and air conditioning energy efficiency

https://doi.org/10.58224/2618-7183-2026-9-5-2
Abstract
This paper presents a field (full-scale) study comparing the thermal performance of a ventilated rainscreen façade (VRF) and a traditional plastered (“wet”) façade on the eastern façade of a nine-story reinforced concrete frame residential building in Southern Kazakhstan during a hot summer period. Sensor-equipped sections of the multilayer wall structure from the 1st to the 9th floors were monitored simultaneously using DS18B20 multichannel contact temperature sensors, an unmanned thermal imaging system (DJI Mavic 3 Thermal), and a handheld thermal imager (Testo 875), providing double, independent validation of surface temperature data. Measurements were taken at 9:00, 12:00, 15:00, and 18:00 on a typical hot day. Although the temperature of the VRF exterior cladding during peak insolation hours exceeded the temperature of the wet façade by up to 2.2°C (reaching 60.1°C on the ninth floor at midday), the temperature of the VRF internal surface was consistently lower than the temperature of the wet façade internal surface on virtually all floors and at all times, the decrease reached 1.55°C, and averaged 1.0-1.3°C during the hottest hours. This apparent paradox, a hotter exterior cladding with a cooler internal surface, is explained by convective decoupling, which is provided by the ventilated air gap: it removes solar-heated air before it has a chance to transfer heat to the load-bearing wall via conduction. Based on the measured temperature difference of the internal surface and its standard heat transfer coefficient, it was shown that the conductive-convective component of the air-conditioning load for rooms behind the VRF is reduced by approximately 7-10% compared to a wet façade during typical hot daytime hours. These results, which relate to the relatively little-studied hot arid/continental climate of Central Asia, expand the evidence base, formed primarily from Mediterranean and Western European studies, and create a natural experimental basis for further thermal and aerodynamic modeling of the ventilated air gap.
PDF

Modeling of an engineering method for calculating the thermal stability of walls with a shielded external surface

https://doi.org/10.58224/2618-7183-2026-9-2-6
Abstract
This paper presents a modeling methodology for an engineering calculation of the thermal stability of external walls with a shielded outer surface forming a ventilated façade system. The objective of the study is to develop a practical design tool for assessing the amplitude attenuation and phase shift of the internal surface temperature under daily climatic fluctuations. The method is based on the solution of a one-dimensional transient heat conduction problem for a multilayer structure subjected to periodic climatic effects. The external boundary condition is defined through an equivalent heat transfer formulation that accounts for shortwave solar radiation, longwave radiative exchange between the screen and the ambient environment, convective heat transfer, and possible ventilation of the air cavity. An engineering calculation algorithm is proposed that incorporates the effect of equivalent solar loading and harmonic variations of outdoor air temperature with high amplitudes of environmental and near-wall air layer fluctuations. A numerical procedure is provided for the “screen – air gap” subsystem, followed by the evaluation of internal surface temperature attenuation and transient heat transfer characteristics. Validation against numerical simulations and experimental data demonstrates a deviation not exceeding 5-10%. The results indicate a significant influence of screen reflectivity, air gap ventilation intensity, and wall heat capacity on improving thermal stability and reducing heat gains during the hot season. The proposed enhanced assessment algorithm can be widely applied in design practice, including the selection of thermal insulation thickness for building envelopes in southern regions, the determination of design loads for ventilation and air-conditioning systems, and the evaluation of indoor thermal conditions under intermittent heating and ventilation regimes. The practical significance lies in the ability to optimize façade system parameters with shielded external surfaces to prevent overheating and improve building energy efficiency. The study is conducted within the framework of ensuring thermal safety of buildings in warm climate conditions.
PDF