Radaykin O.V.

Candidate of Engineering Sciences (Ph.D.), Kazan State University of Architecture and Civil Engineering, Russia

TECHNOLOGICAL FEATURES OF THE CONSTRUCTION OF A DEMOUNTABLE FOUNDATION FOR TOWER STRUCTURES

https://doi.org/10.58224/2618-7183-2022-5-3-17-26
Abstract
The paper proposes a new type of modular demountable reinforced concrete foundation for the construction of tower-type structures. Numerical modeling and design features of the manufacture and installation of the foundation, implemented under patent 2633604 “Demountable foundation for support” for a real tower with a height of 30 meters and a power of a 150 kV wind power plant, are given. The reduction of material consumption is achieved due to the formation of a cavity in each typical module and filling it with soil or any inert material. The result of the proposed solution is to increase the bearing capacity of the foundation as a whole, increase the strength and rigidity of its main joints, as well as simplify installation in comparison with traditional approaches to design. Moreover, the foundation modules, where maximum stresses occur, can be made of fibre concrete.
PDF

THE RELIABILITY COEFFICIENT FOR FIBRE CONCRETE MATERIAL

https://doi.org/10.58224/2618-7183-2022-5-2-51-58
Abstract
One of the main parameters of the method for calculating building structures made of concrete and fibre concrete by limiting states is the reliability coefficient for the material, which characterizes the heterogeneity of the physical and mechanical properties of the material. In national and foreign standards, it takes a constant value of 1.3 (obtained on the basis of direct tests), or 1.5 (obtained on the basis of indirect tests and the use of graduated dependencies). The concrete matrix for the formation of the structure of fibre concrete is most often fine-grained concrete with special additives, which has greater uniformity in comparison with heavy concrete, which cannot but affect the reliability of the composite material in question as a whole: the stock coefficients for fibre concrete should be lower than for normal concrete, which has not been reflected in modern standards for design yet. Starting from interval estimates of the average strength value, a new approach to determining the reliability coefficient for the material, differentiated by the 1st and 2nd groups of limit states, is proposed. The results of calculations according to the proposed formulas for previously conducted tests of steel- and glass-fiber concrete images allowed us to conclude: the introduction of fiber into the concrete matrix of the proposed effective composite composition increases the uniformity of the strength properties of the material, which leads to an increase in the reliability of its use in building structures, a decrease in the value of the reliability coefficient (margin) for the material to 1.164...1.235 for central axial compression and up to 1.172...1.272 – for central axial stretching. The obtained actual coefficients in strength calculations will allow to reveal the supplemented reserves of the bearing capacity of structures made of this material up to 22.4%.
PDF

TECHNOLOGICAL AND DESIGN FEATURES OF DESIGNING A MODULAR REINFORCED CONCRETE FOUNDATION FOR A HIGH-RISE BUILDING OF VARIOUS TYPES

https://doi.org/10.34031/2618-7183-2019-2-6-5-11
Abstract
The paper proposes a new type of modular collapsible reinforced concrete foundation for steel support for various types of structures: power lines, wind power plants, billboards, traffic lights, etc.The foundation has the shape of a cross-hammer in the plan and consists of separate modules manufactured at the factory and connected to each other by concrete dowels and tie bolts on the construction site. At the same time, this technological approach makes it possible to obtain more stable (uniform) strength and deformation properties of both the individual module and the assembled foundation as a whole. Reducing the material consumption is achieved by creating a cavity in each typical module and filling it with local inert material (soil). The central module has an anchor device for joining with the support according to the type of flange connection. This device, along with the use of conventional anchor bolts, involves filling the central module with non-shrinkable fast-hardening steel-fiber concrete. Thus, the positive result of the proposed solution is to increase the bearing capacity of the foundation as a whole, increase the strength and stiffness of its main joints, and simplify installation in comparison with traditional approaches to construction. A comparative calculation of the foundations of the proposed and standard known solutions showed the effectiveness of the first one by at least 17.2%.
PDF

STRESS-STRAIN STATE OF THE SYSTEM “COMBINED TOWER-REINFORCED CONCRETE FOUNDATION-FOUNDATION SOIL” OF HIGH-RISE STRUCTURES

https://doi.org/10.34031/2618-7183-2019-2-6-29-37
Abstract
The aim of the work was to evaluate the effectiveness of the system "combined tower-reinforced concrete foundation-foundation soil" for high-rise structures on the example of a wind power plant (wind turbine) with a capacity of 1.5-2.0 MW using computer modeling in the PC "Ansys". Thus, under the combined tower the article refers to high-rise building, consisting of two parts: the lower composite, the upper – in the form of a thin-walled core-shell closed profile. In both cases, the shell is a pipe with a weak taper. As an analogue, the WPP considered in foreign literature is adopted: the radius of the rotor is R=41 m, the height to the axis of the wind wheel is zhub=80 m. The shell is made of high-strength C355 steel and, unlike the analog in this work, the cavity of the lower part of the tower to a height of 20 m was filled with B60 class concrete. The modeling took into account the spatial work of the elements of the structural system and the physical nonlinearity of the materials from which they are made. At the same time, the Mises strength theory was used for steel, the Williams – Varnake theory for concrete, and the Drukker – Prager theory for the foundation soil. Comparison of the calculation results with the analog showed that the destructive load of the tower increased by 37% due to filling the lower part of it with concrete, which indicates the effectiveness of the proposed solution. In this case, the destruction of the tower with a concrete core and without it occurred from the loss of local stability of the steel shell at the level of the junction of the tower with the foundation (with a compressed zone).
PDF